NDT X Ray Equipment
Heavy Big Parts Welds Universal NDT X Ray Equipment Steel Cylinder Inspection
Heavy Big Parts Welds Universal NDT X Ray Equipment Steel Cylinder Inspection A special challenge in the inspection of heavy and big parts is the difficult part-handling. An efficient solution increases the throughput while reducing the costs. To provide the most convenient solution VisiConsult developed a revolutionary top loader version of the renewned UNC225. Especially for very big and heavy parts like steel castings the handling can become a tedious task that slows down
Unicomp Cabinet NDT X Ray Machine 160KV For Steering Wheel Castings Flaw Detection
Steering Wheel Castings flaw detection by Unicomp Cabinet NDT X-Ray with 160KV System Parameters Dimensions 2100mm*1549mm*2468mm(L*W*H) Equipment weight 3.5T Power 6KW Maximum penetration(AL/FE) 100mm/20mm Detection range Φ500*800mm Load weight 50kg Work environment 5-40° ≤80%HR Install power Three-phase five-wire system AC380V X-ray leakage dose rate ≤1uSv/h X-ray Generator Tube voltage 160kV Power 480W Focal size 0.5mm Detector Image area 145mm x 145mm Resolution 3.0LP/mm
10 KW NDT X Ray Equipment For Casting Defects Heat Sinks / Hot Tears / Cold Flow
Casting defects heat sinks, hot tears, cold-flow, drag-marks, missing material and cracks NDT X-Ray Inspection Application Fields of X Ray Machine UNZ-450 ● Engineering components ● Small aluminum castings, iron castings ● Auto parts, metal products Technical Parameters and Specifications of X Ray Machine UNZ-450 System Parameters Dimensions 2766mm*2813mm*2598mm(L*W*H) Equipment weight 17.5T Power 10 kW Maximum penetration (FE) 80 mm Detection range Φ550*200mm Load weight
160KV Industrial NDT X Ray Machine Multi Manipulator For Aluminum Castings Inspection
160KV Industrial NDT X Ray with Multi Manipulator for aluminum Castings Inspection Technical Data of UNC160s Attribute Respective Value Sample Dimensions Outer width: 250 [mm] max. Outer diameter: 550 [mm] max. Maximum Sample Weight 15 [kg] System Dimension 1480mm*1106mm*2038mm(L*W*H) X-ray Tube 160 [kV] Detector Active Area 250*550mm Pixel Pitch 139 [m] Maximum penetration(AL) 100mm/20mm Detector Resolution 3.1LP/mm Our goal is to solve inspection problems with tailored
Unicomp Foundry Casting NDT X Ray System For Steering Wheel Diecasting Porosity Check
Steering Wheel Diecasting Porosity Quality check with Unicomp NDT X ray System Technical Data of UNC160s Attribute Respective Value Sample Dimensions Outer width: 250 [mm] max. Outer diameter: 550 [mm] max. Maximum Sample Weight 15 [kg] System Dimension 1480mm*1106mm*2038mm(L*W*H) X-ray Tube 160 [kV] Detector Active Area 250*550mm Pixel Pitch 139 [m] Maximum penetration(AL) 100mm/20mm Detector Resolution 3.1LP/mm Our goal is to solve inspection problems with tailored systems,
Real Time Industrial NDT X Ray Equipment For Brake Pads CE / FCC Certificated
CE/FCC Certificated Real Time Industrial NDT X Ray Equipment for Brake Pads Applications of NDT X-ray Machine UNC160: ● Cast parts and Pressure Vessels ● Steel pipe, Cylinder, and Wood ● Epoxy Resin Defect Detection ● Wheel, Tires, and Metal parts Technical Specifications of NDT X-ray Machine UNC160 System Parameters Dimensions 2100mm*1549mm*2468mm(L*W*H) Equipment weight 3.5T Power 6KW Maximum penetration(AL/FE) 100mm/20mm Detection range Φ500*800mm Load weight 50kg Work
UNC160 NDT X Ray Machine For Automotive Brake Disc Diecasting Quality Checking
Chinese NDT X-ray Machine UNC160 for automotive Brake Disc diecasting Quality Checking Technical Specifications of NDT X-ray Machine UNC160 System Parameters Dimensions 2100mm*1549mm*2468mm(L*W*H) Equipment weight 3.5T Power 6KW Maximum penetration(AL/FE) 100mm/20mm Detection range Φ500*800mm Load weight 50kg Work environment 5-40° ≤80%HR Install power Three-phase five-wire system AC380V X-ray leakage dose rate ≤1uSv/h X-ray Generator Tube voltage 160kV Power 480W Focal size
Unicomp Cabinet UNC160 NDT X Ray Radiography Equipment For Brake Disc Casting Defects
Unicomp Cabinet UNC160 NDT X Ray Radiography Equipment for Brake disc casting defects Technical Specifications of UNC160 System Parameters Dimensions 2100mm*1549mm*2468mm(L*W*H) Equipment weight 3.5T Power 6KW Maximum penetration(AL/FE) 100mm/20mm Detection range Φ500*800mm Load weight 50kg Work environment 5-40° ≤80%HR Install power Three-phase five-wire system AC380V X-ray leakage dose rate ≤1uSv/h X-ray Generator Tube voltage 160kV Power 480W Focal size 0.5mm Detector
Unicomp UNC320 NDT X Ray Equipment With Cross Over Manipulator For Aluminum Casting
Automotive steering knuckle aluminum casting tested by Unicomp NDT X-Ray UNC320 with Cross Over manipulator X-ray flaw detection is the difference in the degree of X-ray absorption by using different thicknesses of materials. By using X-ray fluoroscopy and industrial television real-time imaging, the internal defects of materials, parts, and welds are revealed from the film and the image. Such as cracks, shrinkage cavities, pores, slag inclusions, unmelted, incomplete